| TOWER MODEL |
SD 1103 |
SD1105 |
SD1106 |
SD1107 |
SD1110 |
| 19″ RACK MOUNT MODEL |
RMSD 1103 |
RMSD 1105 |
RMSD 1106 |
|
|
| Power(kVA) |
3 |
5 |
6 |
7,5 |
10 |
| INPUT |
|
| Nominal Voltage |
220 V / 230 V |
| Minumum Voltage |
80 V |
| Minumum Voltage (at full load) |
160V |
| Maximum Voltage |
280 V |
| Frequency |
45 – 65 Hz. |
| Power Factor |
>0.99 |
| Input Current Harmonics |
< 6 % |
| OUTPUT |
|
| Power Factor |
0.7 |
| Nominal Voltage |
220 V / 230 V (adjustable) |
| Nominal Current |
13,6 A |
23 A |
27 A |
34 A |
45,5A |
| Wave Form |
Pure Sine Wave |
| Total Harmonic Distortion |
|
| At 100% Linear Load |
< 2,5 % |
| At 100% Non – Linear Load |
< 3,6 % |
| Frequency |
50 or 60 Hz. (adjustable) |
| Frequency Tolerance (line-synchronized) |
0,005 % |
| Static Voltage Regulation(0-100% Load) |
< 1 % |
| Crest Factor |
3 |
| Overload(On Mains)(150% Overload) |
63 Sec |
35 Sec |
49 Sec |
| Overload(On Battery)(150% Overload) |
63 Sec |
35 Sec |
49 Sec |
| Total Efficiency |
> 91,5 % |
| Greenmode Efficiency |
> 97 % |
| BATTERY |
|
| Type |
Maintenance-free lead acid batteries |
| Quantity (pcs) |
14 |
20 |
| Back Up Time (At Nominal Load) |
Internal up to 25 min at tower model |
Internal up to 22 min at tower model |
Internal up to 15 min at tower model |
Internal up to 10 min at tower model |
Internal up to 9 min at tower model |
| Recharging Time |
< 4h / 8 h |
| Discharge Current Wave |
< 10% |
| DISPLAY |
|
| LED Panel |
Line, Bypass, Battery, Inverter, Overload, Fault Indicators |
| LCD Panel |
Load%, Battery Temperature, Input&Output&Battery Voltages, Output Frequency |
| STATIC BY-PASS |
|
| Voltage Tolerance |
10 % (adjustable) |
| Freguency Tolerance |
3 Hz.(adjustable) |
| Transfer Time |
0ms |
| PROTECTION |
|
| Overload Protection |
Bypass transfer time is calculated by simulating a temperature related model of a fuse |
| Short Circuit Protection |
Acts as the ideal current source during the short circuit time |
| Other Protection |
Against excessive (heat, voltage, current) intense battery discharge |
| COMMUNICATION |
|
| Interface (Communication Ports) |
RS232 |
| Dry Contact Signals |
UPS Shutdown, mains failure, low battery, by-pass active, summary alarm |
| ENVIRONMENT |
|
| Operating Temperature |
0 °C ….. +40 °C |
| Storage Temperature |
-15 °C ….. +55 °C |
| Proposed Temp. Extend Battery Life |
20 – 25 °C |
| Humidity |
< 95 % |
| Audible Noise at 1m |
< 50dB |
< 55dB |
| Protection Class |
IP 20 |
| PHYSICAL SPECIFICATIONS |
|
| Tower Type |
|
| Net Weight (without battery) |
43,1 kg |
48,4 kg |
49 kg |
50,9 kg |
54,8 kg |
| Dimension WxDxH (cm) |
27x67x68 |
27x73x78 |
| 19″ Rack Mount Type |
|
| Net Weight (without battery) |
20 kg |
24 kg |
24 kg |
N/A |
N/A |
| Dimension WxDxH (cm) |
48,3x59x13,3 |
N/A |
| STANDARDS |
|
| Standards |
EN 62040-1-1 (safety), EN 62040-2 (EMC) |